| stainless steel pump |
(a) the pump can not be started
One is after closing the motor does not
turn without any sound. This shows that the circuit power supply circuit then
impassibility, should check whether the circuit, whether insurance fuse,
without exception is likely to burn out the motor stater winding, should remove
line replacement. Another is that after closing the motor does not turn and
accompanied by a "buzz" sound. This case should be immediately shut
down inspection. The reason is that there is a 1 power line or the stater winding
is not a phase, the formation of phase. 2 voltage is too low. The reason is
that the power supply voltage is low, the cable is too long and the section is
too small, transformer capacity is too small, should be one by one
investigation. There are 3 foreign bodies in the pump body, bearing damage
death card, "package axis" and "killed" phenomenon, should
the proposed clean water pump inspection.
(b) no water, little or no water after the start of the pump.
The fault reasons are: 1 parts such as
water flow, water diversion tube, shell and other components seriously blocked
or water pipe rupture. At this time often appears to increase the current meter
readings and pointer swing. Should be immediately shut down for inspection and
cleaning up. 2 the normal operation of the motor but the amount of water is
less. The reason is not reasonable pump configuration, the actual head compared
with the pump rated head is too much, the need to replace a higher lift pump.
Also may be a pump reversal, only the lead out of any two can be adjusted
relative to. If the sealing ring or impeller excessive wear and tear, should be
removed in time to replace the. 3 motor running normally but not water, the
main reason is that the water level in the pumping process is too low, can be
transferred to the valve of the water pipe or the water pump will be put to the
following half meter.
(c) the unit turns violent vibration noise
The reasons are: the guide bearing wear
1 pump shaft, in bearing swing, or shaft
bending caused by eccentric wear, the current meter degree increases, the
pointer swing violently, vibration, should immediately stop replacing the guide
bearing or shaft straightening.
2 impeller fastening bolts loose, impeller
and guide shell collision friction, causing the pump body vibration, should be
suspended from the pump, tighten the bolt.
3 thrust bearing wear, so that the front
baffle plate and the flow guide pipe friction, the current table pointer swings
violently. There is a clear friction, should be replaced immediately thrust
bearing, impeller wear should be replaced when the impeller.
4 the motor rotor and the pump rotating
part of the balance is not qualified, the rotation of the unit vibration.
Should take out the motor rotor and pump impeller into action, static balance
test, so that it can reach the equilibrium state.